Central Heating Diesel Fired Burner

Central Heating Diesel Fired Burner

BrandsTurf n Linen
Product Code:Central Heating Diesel Fired Burner
Availability:In Stock
  • ₹177,000.00

  • Ex Tax: ₹150,000.00

Turf N Linen is a trusted name engaged in supplying supreme quality Diesel fired Boiler. This boiler is made as per the prevailing standards of the industry. Our vendors manufacture these boilers using best-g raw material at their state-of-the-art manufacturing plant. In addition to this, these boilers are quality approved at various levels of manufacturing as well as procurement so as to ensure that our patrons are delivered with the defect-free range only. Our offered Hot Water Boiler is reckoned for the following quality attributes: Widely used in central room heating radiator system


Product Details:

  • Precise engineering
  • Optimum performance
  • Low maintenance
  • Thorough efficiency


Specifications:

  • Function: Hot Water Boiler
Central Heating
Boiler Height/mm 1110mm, 1245mm, 1305mm, 1470mm, 1490mm, 1540mm, 1725mm, 1765mm, 2000mm
Boiler Length/mm 1048mm, 1475mm, 1640mm, 1720mm, 1830mm, 1930mm, 2160mm, 2300mm, 2450mm, 2650mm, 2900mm,
Boiler Outlet Inlet R" DN40, DN50, DN65, DN80, DN100, DN125
Boiler Water Volume 100lt, 220lt, 245lt, 250lt, 260lt, 365lt, 420lt, 560lt, 580lt, 670lt, 715lt, 765lt, 1205lt, 1410lt, 1305lt
Boiler Weight 335kg, 435kg, 475kg, 530kg, 570kg, 725kg, 770kg, 900kg, 1010kg, 1215kg, 1505kg, 1755kg 2035kg, 2330kg, 2500kg
Burning Chamber Chamber 45dm3, 123dm3, 149dm3, 204dm3, 208dm3, 292dm3, 351dm3, 418dm3, 475dm3, 704dm3, 762dm3, 941dm3, 1120dm3
Burning Chamber Diameter 310mm, 410mm, 480mm, 550mm, 600mm, 700mm, 750mm, 800mm
Burning Chamber Length 600mm, 930mm, 1130mm, 1150mm, 1230mm, 1480mm, 1680mm, 1830mm, 1980mm, 2130mm, 2230mm
Capacity 1,00,000kcal
Chimney Heigth/mm 905mm, 900mm, 925mm, 990mm, 945mm, 1065mm, 1080mm, 1095mm, 1130mm, 1110mm, 1260mm, 1300mm, 1500mm, 1400mm
CO2 amount 10-11%
Counter Pressure mbar 0.7 1 1,1 0,9 1,5 1,6 1,4 2 2,2, 2,1 2,8 2,6 2,9 3
Efficiency 92-96%
Exhaust Gas Temperature Full Load (celsius) 189, 192, 189, 190, 187, 191 Partial Load (celsius) 129, 132, 130, 126, 127, 131,
Exhaust Gas Connection Diameter 130mm, 200mm, 250mm, 300mm, 400mm, 450mm
Expansion Boiler Inlet 1R", 1 1/4R", 1 1/2R", 2R", 2 1/2R"
Expansion Boiler Outlet 1 1/4R", 1 1/2R", 2R", 2 1/2R"
Filling - Discharge 1/2R", 3/4R", 1R",
Heat Output/kw 93kw, 116kw, 145kw, 174kw, 233kw, 291kw, 349kw, 407kw, 465kw, 582kw, 698kw, 814kw, 1047kw, 1163kw, 80kcal, 100kcal, 125kcal, 150kcal, 200kcal, 250kcal, 300kcal, 350kcal, 400kcal, 500kcal, 600kcal, 700kcal, 800kcal, 900kcal, 1000kcal
Maximum Operating Pressure/bar 4 - 5 - 6 - 8
Operating Temperature 55 - 90celsius
Test Pressure/bar 6 - 7,5- 9 -12
Width 650mm, 750mm, 785mm, 760mm, 910mm, 950mm, 980mm, 1040mm, 1120mm, 1205mm, 1260mm

Write a review

Note: HTML is not translated!
    Bad           Good

Tags: Diesel Fired Boiler